space

To ensure that precautions continue to be carried out and that adequate information is available for checking what is done in practice, a record should be kept showing the information gathered during inspection and monitoring visits and all remedial works carried out as a result.

In addition, the purpose of a Log-Book system is to improve the efficiency and effectiveness of installation and maintenance, and also to provide a record of various tasks and observations so that the plant history can be reviewed at any time by the maintenance staff.

TECHNICAL DATA

We will design, populate and implement on site a
bespoke, electronic data management programme
to enable the Reporting and Logging of the site’s
Legionellosis Management & Control Programme.

The brief features of the Programme include:

  • The data collected and collated during the Risk Assessments process using the ®EDC System is exported automatically to the System. Data not collected by the ®EDC will be uploaded manually.
  • The System has been specifically designed for Legionellosis Management & Control Reporting and Logging – totally “in-house”.
  • The system is fully compliant with ACoP (L8) and HTM04-01 requirements and has been designed in consultation with HSE specialist inspectors.
  • The system is written in Visual Basic with SQL database behind.
  • It produces reports in .pdf format and stores information in SQL.
  • It is totally flexible and can be adjusted to specific client requirements.
  • Runs the site Usage Evaluation and Flushing Programme.
  • Remote support via the 3N system.

BRIEF FEATURES AND BENEFITS

Scheduled Test Programs

  • Clear display of PPM Programme scheduled test programs – plant and site specific
  • Scheduled items status - not started, started, completed, not completed, rescheduled
  • Responsibility for work - client, service provider, both
  • Separate frequency for each day - daily, weekly, monthly, quarterly, annual
  • Prioritisation of outstanding works relative to manpower/resource availability
  • Manpower time allocation and holiday planning pertaining to the PPM Programme
  • Job specifications and instructions
  • Manual printing of all tasks completed when necessary

Paperless PDA inspection and monitoring task completion

  • Automatic uploading of all pending tasks – operator, date, site and plant specific
  • Operator specific Task instructions and paperless form completion using handheld PDAs
  • On-the-job help and instructions for the operator
  • Automatic real-time downloading of all collected task data to central processing terminal
  • Paperless communication between the various users
  • On-line, task and process, training for all users

Non-Conformities

  • Automatically, real-time, generated Non-Conformities from inspection parameters
  • Automatically, real-time, generated and managed display of all Non-Conformities, date, site, task, plant specific
  • Automatically generated Prioritised Recommended Actions
  • Non-Conformities Remedial Action Instructions and Authorisation
  • Report on screen or print all Non-Conformity details, date, site, task, plant specific
  • Automatically, real-time, generated e-mails for Non-Conformities and general communication between users
  • Automatically, real-time, generated update of all system information allowing for easy and inexpensive generation of Risk Assessments allowing for at least a 50% reduction in the costs of the bi-annual Risk Assessment Reviews
  • Automatically, real-time, generated Audit reports for the Status of Legionellosis Management & Control across the Trust

Usage Evaluation and Flushing Process

  • Easy to follow and use Usage Evaluation and Flushing electronic pro-forma on each remote user’s terminal
  • Automatically generated reminder of pending Usage Evaluation and Flushing task
  • Automatically generated responses to central processing terminal for “User Task Compliance” status
  • Listing of all facilities reported as infrequently used and flushed
  • Listing of all facilities reported for removal
  • Automatically, real-time, generated e-mails for Non-Conformities and general communication between remote users and administrator
  • On-line, task and process, training for all users
  • Automatically, real-time, generated Audit reports for the Status of Usage Evaluation and Flushing across the Trust

Security and Data Storage

  • Automatic data back-up
  • Non- changeable back-up format
  • Completely searchable data, including all archived data

Our Log-Books are Designed, Produced and Implemented according to the specific requirements of each client and are based on the demands of each system being logged.

Many years or experience has allowed us to develop successful Logging Programmes for a large number of organisations throughout the UK.


 
Notice Board
N e w s
Health officials seek Legionnaires' source
Wednesday, 8 September 2010
Health officials are trying to find the source of a Legionnaires' disease outbreak which has been linked to the death of a 64-year-old woman.
Legionnaires' fear as woman dies in south Wales
Tuesday, 7 September 2010
A 64-year-old woman has died of suspected Legionnaires' disease in south Wales.
Gardeners warned about Legionnaire's risk
Friday, 3 September 2010
Gardeners are being warned about the risk of Legionnaire's disease from compost, after a pensioner developed the disease after handling some.
Legionnaire's bug in Leeds hospital pipe
Monday, 19 July 2010 12:35 GMT
Legionella bacteria has been found in the water system at a Leeds hospital.
Cardiff bone marrow patient develops Legionnaires
Sunday, 25 June 2010 16:49 GMT